8M Conv. Panel
  • General
  • Feature
  • Specification
This conventional fire control panel forms part of a comprehensive range of conventional and intelligent fire detection equipment. The panel utilises the very latest in microprocessor and surface mount technologies to provide a compact but versatile unit. The EM-8 conventional fire alarm control panels provide eight zones of fire detection and four sounder circuits. The unit has been designed to offer high standards of performance, reliability and quality whilst complying fully with the requirements of EN-54, Parts 2 & 4. The control PCB contains all of the electronics and a switch mode power supply allowing an ‘electronics free’back box to be supplied for ‘first fix’. The moulded cover features custom designed ‘buttons’, which provide a positive tactile action. The housing can accommodate stand-by batteries capable of providing up to 72 hours of operation in the event of mains failure. The EM-8 provides a cost-effective solution to fire detection in most medium sized installations. The panel may be programmed via the in-built push buttons to provide a host of special user applications with standard equipment.
• Robust, moulded housing and steel back box. • Isolate and test facilities. • Conforms to EN54, Parts 2 & 4. • Four fully monitored sounder circuits. • Head removal monitoring with active end of line units supplied. • Fire and fault outputs. • Class change input. • Day/night input. • Configurable options.
mechanical Dimensions (HxWxD): 290 x 350 x 113 mm Weight: 4 Kg (9 lbs) Operating temperature: 0°C to +49°C Humidity: 10% to 93% non-condensing electrical Operating voltage: 230 Vac 50Hz Zone voltage: 17 to 28 Vdc Zone quiescent current: 2.4mA Sounder circuit voltage: 17 to 28 Vdc Max. panel output current: 1.5A Standby batteries: Max. 12Ah
//