A PHP Error was encountered

Severity: Notice

Message: Only variable references should be returned by reference

Filename: core/Common.php

Line Number: 257

A PHP Error was encountered

Severity: Warning

Message: Cannot modify header information - headers already sent by (output started at /home/speipl/public_html/system/core/Exceptions.php:185)

Filename: libraries/Session.php

Line Number: 688

System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Ateis
Master Handset
  • General
  • Feature
  • Specification
The VoCALL Emergency Voice Communications System (EVCS) is designed to fully comply with BS5839-Part 9:2003 for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. An EVCS is a fixed, secure, bi-directional, full duplex voice communication system to assist fire fighters in an emergency in high rise buildings or large sites where Radio communication may not work, and covers the operation of both fire telephones and disabled refuge systems. Where both systems are fitted to a building BS5839 Part 9 specifies these should form a single system. A VoCALL EVCS comprises of three functional blocks, the master handset (VCM) the eight line Exchanges (VCX-8) and outstations, (type A, type B or Jack points), with the quantities of these basic units being adjusted to suit the application.
  • Monitored Handset
  • Large High Contrast Display (4x20 Character)
  • 12 Key Quick Dial Keypad Full Duplex System
  • Up-to Eight Masters Per System Directory Dial Function
  • Full System Event Log (Fault & Configuration)
  • Controls Up-to 256 Lines (32 VCX-8 Exchanges)
  • 16 Character Unique Name Per Line Dual Network Ports
  • Remote Powered
  • Wall, Desk or Rack mount
  • BS5839 Part 9 - 2003 Compliant Eight Status LEDs

Physical

Desk/Wall

Height

: 268mm

Width

: 275mm

Depth

: 85mm

Weight

: 1490g

Material

: Base: Stainless Steel Brushed

: Lid: Zintec, black powder coated

: Sides: Aluminium, Black powder coated

Power Supply

Source

: 230V AC + 20%

Voltage

: 11mA

Current

: 12V SLA 3.2AH

Processing

Architecture

: AVR RISK

Clock

: 16MHz

Memory

: 4K Ram

20K EEProm

128K Flash

Monitoring

: 125mS Asynchronous Watchdog Checksum on EEPROM & Flash

Network Cables

Grade

: Enhanced Cable (per Leg)

Cable (per leg)

: 1 off four Pair (eg Draka 91-0245)

Or

: 2 off four core 1mm CSA Soft Skin

Or

: 4 off 1 Pair MICC Twisted

Distance (per leg)

: 500M soft Skin types, 300M MICC

Monitoring

: Data & Phantom Voltage

Indication & Controls

Fault LEDs

: 4 off yellow (General, Panel, Supply & Exchange)

Status LEDs

: 4 off green (healthy, AC, DC & Network)

LCD

: High Contrast Green/Black LCD, four line twenty-character

5 x 8 pixel format

Keyboard

: 12 Key Telephone Style

Navigation

: 3 Keys (down/left, Accept, up/right)

Standards Compliance

EMC

: EN55103-1, EN55103-2

Product Family

: BS5839-Part 9, BS5588-Part 8

Options

Rack Mount Kit

: Part VCRM

//