System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Ateis
Exchange
  • General
  • Feature
  • Specification
The VoCALL Emergency Voice Communications System (EVCS) is designed to fully comply with BS5839-Part 9:2003 for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. An EVCS is a fixed, secure, bi-directional, full duplex voice communication system to assist fire fighters in an emergency in high rise buildings or large sites where Radio communication may not work, and covers the operation of both fire telephones and disabled refuge systems. Where both systems are fitted to a building BS5839 Part 9 specifies these should form a single system. A VoCALL EVCS comprises of three functional blocks, the master handset (VCM) the eight line Exchanges (VCX-8) and outstations, (type A, type B or Jack points), with the quantities of these basic units being adjusted to suit the application.
-

Physical

Height (Bezel) : 296mm

Width : 210mm

Depth : 80mm

Weight : 1600g

Material : Zintec, Texture Powder coated RAL7032

Power Supply

Voltage : 230V AC + 20%

Current : 11mA

Battery : 12V SLA 3.2AH

Charger : 1A Controlled Impedance

Monitoring : Open, short & High impedance cell

Processing

Status LEDs : AVR RISK

Call : 16MHz

4K Ram

20K EEProm

128K Flash

Monitoring : 125mS Asynchronous Watchdog Checksum on EEPROM & Flash

Network Cables

Grade : Enhanced

Cable (per leg) : 1 off four Pair (eg Draka 91-0245)

Or : 2 off four core 1mm CSA Soft Skin

Or : 4 off 1 Pair MICC Twisted

Distance (per leg) : 500M soft Skin types, 300M MICC

Monitoring : Data & Phantom Voltage

Outstations Cables

Grade : Enhanced

Cable (per Line) : 1 off 2 core (twisted for MICC)

Distance (per leg) : 500M soft Skin types, 300M MICC

Monitoring : DC open, short & earth

Indication & Controls

Fault LEDs : 10 off yellow (General, PSU, 8 lines)

Status LEDs : 2 off green (AC & DC)

Settings : 8 way DIP switch

Standards Compliance

EMC : EN55103-1, EN55103-2

LVD : EN61000-3-2, EN61000-3-3, EN60950

Product Family : ES5839-Part 9, BS5588-Part 8

//