2151_smoke detector_datasheet
  • General
  • Feature
  • Specification
Model 2151 (photoelectric sensor) and model 2151T (photoelectric sensor with thermal) can be used with a variety of adapter bases in several wiring configurations and voltages. Other features include: low current draw, stable performance in high air velocities, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. The 100 series is designed to meet the performance criteria designated by UL. The sensing chamber is sealed against back pressure air flow. The chamber top is covered by a one piece molded screen which minimizes the entry of dirt and insects. This screen can be removed for cleaning. Additional key features include a variety of mounting bases and a full line of accessories. All 100 Series photoelectric smoke detectors contain a unique optical sensing chamber designed to sense smoke particles produced by a wide range of combustion sources. A custom integrated circuit incorporates signal processing to reduce false alarms.
• Sleek, low-profile design • Compatible with 400 Series product • Two LEDs blink in standby, providing 360° visibility • Broad range of adapter bases available with built-in shorting spring • Hand-held sensitivity reader available

Operating Voltage/Alarm Current

See Adapter Base Selection Guide following

Standby Current

120μA Standby (when mounted in a B110LP base)

Sensitivity

1 – 3.18%/ft.

Height

2.0˝ in B401

Diameter

4.1˝ installed in B401; 6.2˝ installed in B110LP

Shipping Weight

5.2 oz

Construction

Flame retardant thermoplastic

Temperature

Photo: 32°F to 120°F (0° to 49°C); Photo/thermal: 32°F to 100°F (0° to 38°C)

UL Listed Velocity Range

Photo: 0 – 3000 fpm (0 – 15.2 m/s)

Humidity Range

10% – 93% RH non-condensing

Smoke Detector Spacing

On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (900 sq. ft.) may be used as a guide. Other spacing may be used depending on ceiling height, high air movements, and other conditions or response requirements.

//