A PHP Error was encountered

Severity: Notice

Message: Only variable references should be returned by reference

Filename: core/Common.php

Line Number: 257

A PHP Error was encountered

Severity: Warning

Message: Cannot modify header information - headers already sent by (output started at /home/speipl/public_html/system/core/Exceptions.php:185)

Filename: libraries/Session.php

Line Number: 688

System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Ravel
RE1504-08
  • General
  • Feature
  • Specification
none
  • As per NFPA-72 standards.
  • Rugged CRCA sheet with powder coated finish.
  • Network able / Standalone panel.
  • 4/8 Class B conventional initiating device circuit (IDC).
  • All zones accept smoke detectors and any normally open contact device.
  • Any Zone can be configured as Alarm or supervisory Zone.
  • Class B Notification Appliance Circuits (NAC).
  • Operates on 220v 50Hz, AC Mains power supply
  • Standby (battery) backup 24v DC power supply with built in charger.
  • All field wiring circuits are supervised.
  • AC Low voltage cutoff.
  • Programmable NAC.
  • Programmable IDCs.
  • Programmable AC loss delay.
  • Programmable Trouble reminder.
  • Programmable Form -C relay for fire / Fault / Supervisory.
  • 2 Form-C relay for Fire.
  • Alarm Verification Facility. **
  • 1000 history events with RTC.
  • Error free Fire / Fault status in unambiguous colored LED indication.
  • Main, Standby status audible and visual indication.
  • Battery Low visual warning with audible tone.
  • Zone Isolation Facility.
  • Peer to Peer networking facility (upto 16 panels ) .
  • Ground fault annunciation facility at 0 ohms.
  • All field wiring circuits are Power limited except 220v A.C. and Battery.
  • Advanced Features for the System Sensor series 300 detectors.
  • 32 Detectors per Zone.
  • Active Scan Devices facility.
  • Individual detector address with location.
  • Primary Power 220VAC ± 10%, 50 Hz, 2.5Amps. Standby Power 24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery). Operating Condition Operating Temperature 15 - 35° C/60-95° F. Relative Humidity 93 ± 2% RH (non-condensing) at 32 ±2° C/90 ±3° F. Charging Circuit Charging Voltage 28.4V, ±0.2V Charging Current 800mA (Max.). Initiating Device Circuits All zones are Class B Style C operation. Normal Operating Voltage: 14 - 20 VDC. Alarm Current: 15 - 30mA. Short Circuit Current: 40mA Maximum. Loop resistance: 40 ohms Maximum. End-Of-Line Resistor: 4K7, 1/2watt Standby Current: 6mA (2mA for Detectors) Notification Appliance Circuits Class B Style - Y wiring Operating Nominal Voltage: 24VDC Special Application Current for NACs: 1Amps Line Drop: 1.8V End-Of-Line Resistor: 4K7, 1/2watt Resettable D.C. Power Operating Voltage: Supervised 24VDC regulated, 300mA Max. (for 4 wire smoke detector) Common Three Form C Relays Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC. Power Factor: 0.6 Ordering Information RE 1504 W/R - 4 IDC RE 1508 W/R - 8 IDC W- White Colour; R - Red Colour. Dimension of panel: 425 X 350 X 110mm ( Width x Height X Depth)
    //