RE-386CO
  • General
  • Feature
  • Specification
RE-386CO Conventional gas (CO) detector is one of the most advanced design used to detect toxic carbon monoxide gas engineered with electrochemical sensor. RE-386CO conventional gas (CO) detector are suitable for use with conventional fire detection control panel as well as addressable fire detection control panel that can accept conventional type detectors via Zone Module. Advanced electronics in conjunction with a semiconductor gas sensor provides early detection of carbon monoxide (CO).
  • Advanced algorithms provide advanced detection, discrimination.
  • Stable gas sensing chamber. No adjustment or replacement required
  • High immunity against unwanted alarms
  • Surface-mount device (SMD) circuit board design
  • 4-wire system operation
  • Detector auto-reset once gas levels fall below alarm threshold levels
  • Internal reed switch for hush and test functions
  • DC 24 V operation
  • N/O alarm relay output
  • 70 dB internal sounder
  • Easy installation. No programming required
  • Connects to Zone Module for use with addressable control and indicating equipment
  • Sleek low-profile housing design
  • Low maintenance
Operating Voltage(21 ~ 27) VDC Start-up current<120Ma Start-up time<10min Quiescent Current20 mA Alarm Current (max)20mA Sampling Time3s – 5s Reset Voltage<1 V Reset Time< 5s Alarm response threshold 70 !L/L for 60 min ~ 240 min 150 !L/L for 10 min ~ 50 min 400 !L/L for 4 min ~ 15 min 50 !L/L for 60 min ~ 90 min 100 !L/L for 10 min ~ 40 min 300 !L/L for < 3 min Alarm relaySPST. N/O1.0 A @ DC 30 V / 0.5 A@AC 125 V Auto reset time< 3s Sounder output>70 db @ 3m Operating temperature-10° C ~50° C Operating humidity0 % ~ 95 % RH, non-condensing Storage temperature-25° C ~80° C Operating humidity0 % ~ 98 % RH, non-condensing Quiescent condition indicatorSingle continuous emitting green LED Alarm condition indicatorFlashing red LED Dimensions (excluding contacts)100mm X 38 mm Ingress protection ratingIP-32
//