Home --> Fire Alarm Systems
RE-120gr
  • General
  • Feature
  • Specification
NONE
Rugged CRCA sheet with powder coated finish. Operates on 220V, A.C supply Battery backup with built in charging. 16 X 2 LCD Dot Matrix Display. Evacuate and Key pad Enable, Disable Facility. Low battery visual warning with audible tone. 2 Form C Relay output for fire. One Programmable relay for fire/fault/solenoid on /timer on. Remote fire indication with Audible Tone. Compatible to all types of conventional detectors. Zone Disable (Isolation) facility with loop voltage cut off. Resettable 24v DC output for 4 wire detectors . Three 24V Hooter Output (Fire, after Cross zone, after gas release) . Two mode operation facility (Auto / Manual). Programmable FAP input selection Facility. Programmable Solenoid Output with On and OFF Timer. Main / Standby Cylinder output Facility . Gas Inhibition and Instant release facility. Manual Gas Release with or without timer. Actuator pressure low sensing facility.
Power 220 VAC , 50 Hz. Wire size: 1.5 Sq. mm with 600V insulation Battery (Lead Acid only) Charging Voltage : 27.9 VDC. Charging Capacity : 7 Amp Hour Battery Max. System Quiescent Current: 80mA + (2.4mA for Detector s Initiating Device Circuits (Zone Circuit) All zones are Class B wiring Normal Operating Voltage : Nominal 24 VDC Alarm Current : 15 - 35mA threshold Short Circuit Current : 40mA Maximum Loop resistance : 50 ohms Maximum End-Of-Line Resistor : 4.7K, 1/4watt Standby Current : 6.8mA (2.4mA for Detectors) Notification Appliance Circuits (Sounder/Hooter Circuit) Operating Nominal Voltage: 24 VDC Hooter (NACs) output : 0.5A (Each) End-Of-Line Resistor : 4.7K, 1/4watt Solenoid Relay Output Circuits Operating Nominal Voltage : 24 VDC Solenoid output : 0.75A (Each) 2No’s of Hooter (NACs) output : 0.3A (Each) End-Of-Line Resistor: 4.7K, 1/4watt (for Solenoid Output) Remote Outputs Fire Contact (C, NO, NC) : 220v AC/30v DC@ 1A Fault Contact (C, NO, NC ): 220v AC/30v DC@ 1A Timer Contact (C, NO, NC): 220v AC/30v DC@ 1A 24 VDC Power For remote devices Operating Voltage: 24VDC, 500mA Max. RS 24 VDC Power For Four Wire devices Operating Voltage: 24VDC, 500mA Max. Dimension of the panel : 400 x 300 x 100 mm ( length x height x width)
//