System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Fire Alarm Systems
RE-15ar
  • General
  • Feature
  • Specification
NONE
Fully complies with UL -864 and NFPA-72. Rugged CRCA sheet with powder coated finish.Operates on 120-220v 60 / 50 Hz, A.C. Mains power supply. Standby (battery) backup 24v D.C. power supply with built-in charger . All zones accept smoke detectors and any normally open Contact device. Any Zone can be configured as Alarm or supervisory Zone. Error free Fire / Fault status in unambiguous colored LED indication. System ON indication. 16x2 Dot Matrix LCD Display. 4 Class - B / 2 Class - A Initiating device circuits (I.D.C). 2 Class - B Releasing Agent Circuits (R.A.C). 2 Notification Appliances Circuits (N.A.C). 100 Events Log with RTC. 4 Programmable Input circuits for manual release /Abort/Pressure Switch/Actuator low pressure. Programmable 24v DC output (Steady/Resettable/Pre-Release). Zone Isolation Facility. Walk test Facility. All Wiring Circuits are supervised. Programmable RAC's with Count down Timer. Programmable NAC's. Programmable Trouble reminder facility. Programmable A.C. loss Delay. Earth Fault annunciation facility All Field Circuits are power limited except 120-220v AC and Battery. RS 485 Communication Facility (Optional for Zone wise contact / MODBUS Two Modes of Operation (Auto /Manual).
Primary Power (RE-SMPS-4A-R1) 120 - 220VAC ± 10%, 50 Hz, 2.5Amps. Standby Power 24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery). Operating Condition Operating Temperature 0 - 49° C/32-120° F. Relative Humidity 93 ± 2% RH (non-condensing) at 25 ±2° C/77 ±3° F. Charging Circuit Charging Voltage 28.4V, ±0.2V With current 800mA (Max). Initiating Device Circuits Class A/B Style B/C operation (Programmable). Normal Operating Voltage: 14 - 21 VDC. Alarm Current: 15 - 30mA. Short Circuit Current: 45mA Maximum. Loop resistance: 100 ohms Maximum. End-Of-Line Resistor: 3K9, 1/2watt Standby Current: 7mA (2mA for Detectors) Notification Appliance Circuits Class B Style - Y wiring Operating Nominal Voltage: 24VDC Special Application Current for NACs: 0.5A per circuit Line Drop: 1.8V End-Of-Line Resistor: 3K9, 1/2watt Releasing Agent Circuits Class B Style - Y wiring Operating Nominal Voltage: 24VDC Special Application Current for RACs: 2A Line Drop: 1.8V End-Of-Line Resistor: 3K9, 1/2watt D.C. Output Power Supervised 24VDC regulated, 1A Max. (for 4 wire smoke detector) Common Four Form C Relays Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC. Power Factor: 0.6 Dimension of the panel : 450 x 340 x 120 mm ( length x height x width )
//