Home --> Fire Alarm Systems
RE-700
  • General
  • Feature
  • Specification
The RE – 700 is a 2 – 128 zone microprocessor based conventional Fire Alarm Control Panel. The Panel accepts water flow devices, conventional input devices like 2 wire smoke detectors, pull stations and other normally open contact devices. The Outputs include notification appliance circuits (NACs / sounders), Two Form –C relays for Fire and one relay for fault. And also communication port RS485 to interface with remote annunciator. This panel is field programmable via the front panel keypad. It supervises all wiring, AC voltage and Battery level.
_ 2 - 128 Class B initiating device circuit (IDC / Zone Circuits). _ All zones accept smoke detectors and any normally open contact device. _ One Class B Notification Appliance Circuits (NAC / Sounder). _ Fully complies with IS 2189: 1988. _ Rugged CRCA sheet with powder coated finish. _ Modular construction. _ Operates on 220v, AC Mains power supply. _ Standby (battery) back up 24v DC power supply with built in charger _ Error free Fire / Fault status in unambiguous colored LED indication. _ 20 X 4 LCD Display. _ System ON indications. _ Main, Standby status with visual/audible indication. _ Battery Low visual warning with audible tone. _ Event storage with RTC. _ Form–C relays for Fire and fault. _ Lamp Test facility. _ Walk Test facility. _ Zone Isolation facility with loop voltage cut off. _ Compatible with all types of conventional detectors, Pull Stations and any normally open contact devices.
AC Power 220 VAC, 50 Hz, +10%, -15%. Wire size: 1.5 Sq. mm with 600 V insulation Battery (Lead Acid only) Charging Current: Constant Voltage – 27.6v @ 0.8A (Max.). Charging Capacity: 7 Amp Hour Battery (Higher size are request). System Quiescent Current: 50mA + (4.4 – 6.8mA per zone) Initiating Device Circuits (Zone Circuit) All zones are Class B operation Normal Operating Voltage: Nominal 24 VDC Alarm Current: 15 – 35mA threshold Short Circuit Current: 40mA Maximum Loop resistance: 100 ohms Maximum End-Of-Line Resistor: 4.7K, 1/4watt Standby Current: 8.2mA (4mA for Detectors) Notification Appliance Circuits (Sounder Circuit) Class – B wiring Operating Nominal Voltage: 24 VDC Current for all NACs: 0.2A per Zone End-Of-Line Resistor: 4.7K, 1/4watt Three Form – C Relays Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC. 24 VDC Power Operating Voltage: 24VDC, 500mA Max. RS485 Communication Port Max. Distance: 1.5Km Max.
//