Fillup short form for request catalog


Home --> Ravel
RE150d
  • General
  • Feature
  • Specification
The RE – 150D is a 2 zone microprocessor based conventional Fire Alarm Control Panel. The Panel accepts water flow devices, conventional input devices like 2 wire smoke detectors, pull stations and other normally open contact devices. The Outputs include Notification Appliance Circuits (sounders), Three Form – C relays for alarm. It supervises all wiring, AC voltage and Battery level.
_ Fully confirms IS 2189: 1988 _ 16SWG Rugged CRCA with powder coated finish. _ Modular construction. _ Operates on 230V, A.C supply. _ Battery backup with built in charging. _ 16x2 LCD Dot matrix Display. _ Fire / Fault status in unambiguous coloured LED indication. _ Low battery / battery fail warning audio / visual indication. _ A.C fail audio / visual warning. _ Charger fail audio / visual warning _ System on, AC on, Battery on & Charger on indications _ Potential Free Relay Contacts for actuators. _ Lamp test facility. _ One man walk test facility. _ Compatible to all types of conventional detectors. _ Twin RED LED indication for fire. _ Zone Isolation facility with loop voltage cut off. _ Earth Fault with Audio and Visual Indications. _ Supervised Sounder 24v DC output for External notificationdevices (Sounder, Bell, etc.).
AC Power 220-240 VAC, 50 Hz. Wire size: 1.5 Sq. mm with 600V insulation Battery (Lead Acid only) Charging: Constant Voltage – 27.6v @ 0.5A Charging Capacity: 26 Amp Hour Battery Max. System Quiescent Current: 70mA + (4.4 – 6.8mA per zone) Initiating Device Circuits (Zone Circuit) All zones are Class B wiring Normal Operating Voltage: Nominal 24 VDC Alarm Current: 15 – 35mA threshold Short Circuit Current: 42mA Maximum Loop resistance: 50 ohms Maximum End-Of-Line Resistor: 4.7K, 1/4watt Standby Current: 6.8mA (2.4mA for Detectors) Notification Appliance Circuits (Sounder Circuit) Class – B wiring Operating Nominal Voltage: 24 VDC Hooter (NACs) output: 0.2A X No. of zone End-Of-Line Resistor: 4.7K, 1/4watt Three Form – C Relays Relay Contact Rating: 2Amps @ 30 VDC, 2Amps @ 30VAC (Fire – 3 No’s). 24 VDC Power – For remote devices Operating Voltage: 24VDC, 500mA Max.
//