System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Fire Alarm Systems
RE120GR
  • General
  • Feature
  • Specification
The RE – 120GR is a 2 zone Dedicated microprocessor based conventional Fire Alarm Gas Release Panel. The Panel accepts water flow devices, conventional input devices like 2 wire and 4 wire smoke detectors, pull stations and other normally open contact devices in Fire Zone inputs. The Outputs include three numbers of Notification Appliance Circuits (sounders)(2No’s for gas release functions and 1No. for Fire Alarm, Four Form – C relays for fire (2No’s), fault (1 No.) and 1 No. for timer. It supervises all wiring, AC voltage and Battery level.
_ Rugged CRCA sheet with powder coated finish. _ Modular construction. _ Operates on 220V, A.C supply. _ Battery backup with built in charging. _ 16 X 2 LCD Dot Matrix Display. _ Key pad Enable, disable and evacuate facility. _ Low battery visual warning with audible tone. _ System on, AC on , Battery on indications. _ Relay output for actuators. _ Remote fire indication with Audible Tone. _ Compatible to all types of conventional detectors. _ Zone Disable (Isolation) facility with loop voltage cut off. _ Resettable 24v DC output for 4 wire detectors. _ Three 24 VDC output for External notification devices (Fire, after cross zone, after gas release). _ Two modes of operation (Auto / Manual). _ Programmable remote input. _ Programmable Solenoid Output with On and Off Timer count down. _ Manual Gas Release & Inhibit. _ Programmable Pressure Switch facility. _ Actuator Pressure low sensing input.
AC Power 220 VAC (+10%, -15%), 50 Hz. Wire size: 1.5 Sq. mm with 600V insulation Battery (Lead Acid only) Charging Voltage: 27.9 VDC. Charging Capacity: 7 Amp Hour Battery Max. System Quiescent Current: 70mA Initiating Device Circuits (Zone Circuit) All zones are Class B wiring Normal Operating Voltage: Nominal 24 VDC Alarm Current: 9 – 32mA threshold Short Circuit Current: 40mA Maximum Loop resistance: 100 ohms Maximum End-Of-Line Resistor: 4.7K, 1/4watt Standby Current: 6.8mA (2.4mA for Detectors) Notification Appliance Circuits (Sounder/Hooter Circuit) Class – B wiring Operating Nominal Voltage: 24 VDC Hooter (NACs) output: 0.5A End-Of-Line Resistor: 4.7K, 1/4watt Remote Outputs Fire Contact (C, NO, NC): 220v AC/30v DC@ 1A Fault Contact (C, NO, NC): 220v AC/30v DC@ 1A Timer Contact (C, NO, NC): 220v AC/30v DC@ 1A RS 24 VDC Power – For Four Wire devices Operating Voltage: 24VDC, 300mA Max.
//