A PHP Error was encountered

Severity: Notice

Message: Only variable references should be returned by reference

Filename: core/Common.php

Line Number: 257

A PHP Error was encountered

Severity: Warning

Message: Cannot modify header information - headers already sent by (output started at /home/speipl/public_html/system/core/Exceptions.php:185)

Filename: libraries/Session.php

Line Number: 688

System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Morley-IAS
ZXra_ZXrp_repeaters
  • General
  • Feature
  • Specification
• The Remote Repeater provides an extension to the operation of the Fire Alarm Control Panel (FACP). Both types of Repeater show (repeat) the operational state of the FACP using the 2x40 LCD and the LED indicators. • The ZXr-P Passive Repeater will only show (repeat) the operational state of the FACP. • The ZXr-A Active Repeater will show (repeat) the operational state of the FACP and can control the FACP using the SOUND ALARMS, SILENCE / RESOUND, MUTE BUZZER, ACCEPT and SYSTEM RESET functions. • The Repeaters are connected to the FACP via the Peripheral Bus RS485 data link. The FACP supervises the ZXr-A Active Repeater. A Fault will be indicated, at the FACP, if communications is lost with the Repeater. • The ZXr-A / ZXr-P Repeaters are compatible with the ZX1e, ZX2e, ZX5e and older ZX Range of Fire Alarm Control Panels1. • An optional Bezel Kit, containing back box and bezel, is available for pre-installation (P/N 002-600-002). • The ZXr-A has in-built self-test functions that can be invoked using the buttons. The LCD contrast can be adjusted on both repeaters.
-
Criteria Details Mechanical Construction Mild steel sheet enclosure with 3 mounting holes, 5 x 20mm knockouts in top and 3 x 20mm knockouts in rear wall. All displays and controls are carried on the enclosure door. Dimensions 165.0mm (h) x 253.5mm (w) x 50.0mm (d) Weight 1.7kg approx. Terminals External connections are made using screw terminals capable of accepting cable sizes between 0.5mm2to 2.5mm 2 (14-22AWG). Environmental Climatic Classification 3K5, (IEC 721-2-3) Operating Temperature -5°C to +45°C (recommended +5°C to +35°C) Humidity 5% to 95% R.H. non condensing Height above sea level 2000m Panel Sealing IP30 (EN60529) Vibration EN60068-2-6, 10-150Hz at 0.981ms -2(meets the requirements of EN54-2/4) EMC Emissions: EN50081-1. Immunity: EN50130-4 Safety EN60950 Electrical Operating Voltage 18-32V dc Quiescent Current 60mA @ 24V (Backlight off) Alarm Current 90mA @ 24V (Backlight on), 100mA @ 18V Maximum Fault Current Absolute maximum = 600mA. Resetting thermal fuse . nominal 250mA. Communications RS485 2-wire serial communications link Address Range 0, 1-126 (0 is unmonitored) Controls and Indications Display 2 x 40 character liquid crystal display (LCD) with back light illumination Status Indicators LED Indicators for FIRE, FAULT, DISABLEMENT, ACCEPTED, SILENCED, COMMUNICATIONS FAILURE and POWER. Push Buttons Control keys for RESET, MUTE BUZZER, ACCEPT, TEST, SOUND ALARMS and SILENCE / RESOUND.
//