Home --> Morley-IAS
Dimensions_DX2e_Data_Sheet_0311
  • General
  • Feature
  • Specification
The Dimension series of intelligent multi protocol fire alarm control panels from Morley-IAS Fire Systems have been developed based on two concepts - simplicity and reliability   Simply, fix the control panel to the wall, connect the field wiring and everything else is configured in the software. Even programming the control panel is simple. No computer is required and it only takes a few key presses to have a working fire alarm system. First, set the protocol for the loop devices. Second, “Autolearn” the panel and finally, “Reset” the panel. The control panel is now protecting the building. The Dimension series provides additional features allowing:- programmable text messages to identify the exact location of each field device, a class change input for schools, coincidence and verification detection (false alarm management), sensitivity adjustment (between day and night), programmable function buttons, input/output logic and extensive event logging. A feature rich fire alarm control panel constructed from high specification components to help both the installer and the end user.
• Complies with EN54 part 2 and part 4 • 40 fire zone LED indicators • 2 independent sounder circuits • 500mA Universal Loop Driver • Supports Apollo (Xplorer, XP95 and Discovery), Hochiki (ESP), Morley-IAS & System Sensor • 7 day timers • Day/Night mode switching • Onboard monitored inputs • Programmable user function keys • Event logging • Onboard diagnostics • User access restriction • All metal enclosure • Plug-in connectors • Optional internal printer • PC configuration software (optional)
Mechanical Dimensions (H x W x D): DX1e-20S 245 x 380 x 110 mm DX1e-40M 380 x 380 x 130 mm DX1e-40MP 380 x 380 x 130 mm Weight (Excluding batteries): DX1e-20S(F) 5 Kg DX1e-40M(F) 7 Kg DX1e-40MP(F) 7.2 Kg Material 1.2mm Zintec powder epoxy coated Colour RAL 9001 - Cool Grey Knockouts Top: 19 x M20 Bottom: 3 x M20. Temperature Operating: 0°C to +45°C Storage: 10°C to +55°C Relative Humidity 5% to 95% non condensing. Electrical Operating voltage 230Vac (+10%, -15%) 50-60 Hz PSU Rating DX2e-40M(F) 24 Vdc 4A DX2e-40MP(F) 24 Vdc 4A DX2e-40L(F) 24 Vdc 4A DX2e-40LP(F) 24 Vdc 4A Standby Batteries DX2e-40M(F) 2 x 7Ahr or 2 x 12AHr DX2e-40MP(F) 2 x 7Ahr or 2 x 12AHr DX2e-40L(F) 2 x 12AHr or 2 x 17AHr DX2e-40LP(F) 2 x 12AHr or 2 x 17AHr Auxiliary output* +24 Vdc 250mA fused Loop Capacity** 2 Loops, 500mA, 126 devices Apollo Protocols, 126 devices Hochiki Protocol, 198 devices Morley-IAS Protocol, 198 devices System Sensor Protocol Output Relays Fire relay: Single pole changeover 30Vdc 1A Fault relay: Single pole changeover 30Vdc 1A Aux relay: Programmable single pole changeover 30Vdc 1A Onboard Inputs Keyswitch: programmable for select functions Input #1: programmable (monitored) for select functions Input #2: programmable (monitored) for select functions Data Ports 1 x RS 485 (Repeater connections) 1 x RS232 (PC Programming) Sounder Circuits 2 output circuits, 1A available across both circuits.*
//