A PHP Error was encountered

Severity: Notice

Message: Only variable references should be returned by reference

Filename: core/Common.php

Line Number: 257

A PHP Error was encountered

Severity: Warning

Message: Cannot modify header information - headers already sent by (output started at /home/speipl/public_html/system/core/Exceptions.php:185)

Filename: libraries/Session.php

Line Number: 688

System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Fire Alarm Systems
ZXr-A or ZXr-P Installation, Operations Manual
  • General
  • Feature
  • Specification
• The Remote Annunciator provides an extension to the operation of the Fire Alarm Control Panel (FACP). Both types of Annunciator show (repeat) the operational state of the FACP using the 2x40 LCD and the LED indicators. • The ZXr-P Passive Annunciator will only show (repeat) the operational state of the FACP. • The ZXr-A Active Annunciator will show (repeat) the operational state of the FACP and can control the FACP using the FIRE DRILL, ALARM SILENCE (& RESOUND), TROUBLE SILENCE, ACCEPT and SYSTEM RESET functions. • The Annunciators are connected to the FACP via the Peripheral Bus RS485 data link. The FACP supervises the ZXr-A Active Annunciator. A Fault will be indicated, at the FACP, if communications is lost with the Annunciator. • The ZXr-A / ZXr-P Remote Annunciators are compatible with the ZXa-UL and ZXe-UL Range of Fire Alarm Control Panels. • An optional Bezel Kit, containing back box and bezel, is available for pre-installation (P/N 020-600-002). • The ZXr-A has in-built self-test functions that can be invoked using the buttons. The LCD contrast can be adjusted on both Annunciators.
-
Mechanical Construction Mild steel sheet enclosure with 3 mounting holes, 5 x 20mm knockoutsin top and 3 x 20mm knockouts in rear wall. All displays and controlsare carried on the enclosure door. Dimensions 165.0mm (h) x 253.5mm (w) x 50.0mm (d) Weight 1.7kg approx. Terminals External connections are made using screw terminals capable of accepting cable sizes between 0.5mm2 to 2.5mm2 (14-22AWG). Environmental Climatic Classification 3K5, (IEC 721-2-3) Operating Temperature 0°C to +49°C (recommended +5°C to +35°C) 5% to 95% R.H. non condensing Height above sea level 2000m Panel Sealing IP30 (EN60529) Vibration EN60068-2-6, 10-150Hz at 0.981ms-2 (meets the requirements ofEN54-2/4) EMC Emissions: EN50081-1. Immunity: EN50130-4 Safety EN60950 Electrical Operating Voltage 21.5 – 25.5 V DC Quiescent Current 60mA @ 24V (Backlight off) Alarm Current 90mA @ 24V (Backlight on), 100mA @ 18V Maximum Fault Current Absolute maximum =600mA Resetting thermal fuse – nominal 250mA. Communications RS485 2-wire serial communications link Address Range 0, 1-126 (0 is unmonitored)
//