EDW-100
  • General
  • Feature
  • Specification
The EDW-100 is an Industrial Ethernet to serial adapter or Ethernet Terminal Server. The serial interface is selectable between RS-232 and RS-422/485. The Ethernet interface is 10/100BASE-T and supports the following networking protocols: TCP, UDP, ICMP, IGMP, HTTP, ARP. Two EDW-100 can be used to provide a serial point to point link over an Ethernet network using either UDP or TCP. When using TCP the EDW-100 can be configured as client or server. In addition to a transparent serial point-to-point link and ethernet to serial adapter, the EDW-100 MG can also be configured to act as a Modbus gateway.
… Packing algorithm that enables the user to decide how and when the serial data should be encapsulated in a TCP or UDP data frame and sent out on the network. … Galvanic isolation, this feature eliminate communication errors. One of the most common errors is caused by potential differences between interconnected equipment. … Redundant power supply with wide input range. Theses feature along with the high EMC immunity enables the device to be used in projects where a high degree of reliability is required.
Power Rated voltage 12 to 48 VDC Operating voltage 10 to 60 VDC Rated current 250 mA @ 12 VDC 125 mA @ 24 VDC 63 mA @ 48 VDC Rated frequency DC Maximum inrush current @ 10 ms 0.3 A2s @ 48 VDC Polarity Reverse polarity protected Redundant power input Yes Isolation to All other 3 kVrms Connection Detachable screw terminal Connector size 0.2 – 2.5 mm2 (AWG 24 – 12) RS-422/485 Electrical specification EIA RS-485 2-wire or 4-wire twisted pair Data rate 300 bit/s – 115.2 kbit/s Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits Protocol Transparent, optimised by packing algorithm Retiming Not applicable Turn around time < 3 bits Circuit type TNV-1 Transmission range ≤ 1200 m, depending on data rate and cable type (EIA RS-485) Settings 120 Ω termination and fail-safe biasing 680 Ω Protection Installation Fault Tolerant (up to ±60 V) Isolation to Power 3 kV Ethernet 1 1.5 k Vrms Connection Detachable screw terminal Connector size 0.2 – 2.5 mm2 (AWG 24 – 12) Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails* Conductive housing No
//