Home --> Morley-IAS
Repeater Panels
  • General
  • Feature
  • Specification
The Morley-IAS repeaters are compact remote control units for Morley-IAS intelligent multi protocol fire alarm control panels. These units, along with other I/O peripheral devices and the external printer further enhance the flexibility and functionality of our fire alarm control panel range. The repeaters provide an extension to the operation of the fire alarm control panel. There are two types available - passive with indications only and no controls, or active with both controls and indicators. Both display the operational state of the control panel using the 80 character LCD display and the 7 LED status indicators. In addition to the general status indicators the Active repeater is fitted with key operated "Access Enable" switch for the control functions. Individual buttons are provided for System Reset, Mute, Accept, Sound Alarms, Silence/Re-sound Alarms and Self test. Thus enabling control functions to be duplicated in strategic locations around the installation.
Compatible with Morley-IAS intelligent multi-protocol fire alarm control panels Connects to RS485 peripheral bus Active or Passive options Backlit adjustable alphanumeric display General status LEDs Controls for system reset, accept, mute, silence alarms and self test (active repeater only) ""Access Enable"" key-switch on active
mechanical Weight 1.7Kg (approx) Operating Temperature +5 ºC to +45 ºC Maximum Humidity 10% to 93% non-condensing electrical Operating voltage 18 to 32 Vdc Operating current 90mA (Quiescent) 120mA (Alarm) Terminals Maximum cross section 2.5mm2 LED indications Fire, Fault, Disabled, Accepted, Silenced, Power, Communications loss. User controls Keyswitch activated - System Reset, Sound Alarms, Silence/Resound, Mute, Accept and Self Test.
//