A PHP Error was encountered

Severity: Notice

Message: Only variable references should be returned by reference

Filename: core/Common.php

Line Number: 257

A PHP Error was encountered

Severity: Warning

Message: Cannot modify header information - headers already sent by (output started at /home/speipl/public_html/system/core/Exceptions.php:185)

Filename: libraries/Session.php

Line Number: 688

System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Fire Alarm Systems
MI-MCP-FLEX
  • General
  • Feature
  • Specification
The MI-MCP Series Manual Call Points are designed to provide a manual alarm interface to Morley IAS’s fire alarm control panel. Installation efficiency, flexibility and compliance with the latest standards are at the heart of the call point range. The unique ‘plug and play’ concept is designed specifically to reduce installation time by using a terminal block which can be wired during the initial installation cabling with a link (P102) to provide continuity for testing. During the commissioning phase, the links are removed and the terminal block is simply inserted into the connector at the back of the unit. No re-termination is required. Both break glass, supplied, and re-settable operating elements (PS230) can be used in the standard unit. Operation of the resettable element, as well as being indicated by the units LED, is also indicated by a yellow strip on the element which becomes visible when activated. With the addition of a hinged transparent cover (PS200) the element may be protected against accidental operation and may be further protected by using a cover seal (PS056) which requires breaking in order to operate the unit.
• Unique ‘Plug & Play’ installation concept • Re-settable operating element option • Analogue addressable communications • Semi-Flush or surface mounting • Fully compliant with EN54, Part 11 • Backward compatibility • Enhanced aesthetics • Integral LED • Integral loop isolation option
mechanical Dimensions: Semi-flush mounting: 89 x 93 x 27.5 (WxHxD) Surface mounting: 89 x 93 x 59.5 (WxHxD) Weight: Semi Flush: 110g Surface: 160g IP Rating: IP24D Operating Temperature: -30°C to +70°C Relative Humidity: 0% - 95% non-condensing electrical Operating Voltage: 15V to 30Vdc max Current Consumption: Quiescent (without isolator) 260μA Quiescent (with isolator) 360μA Alarm Current: 6mA (both)
//