A PHP Error was encountered

Severity: Notice

Message: Only variable references should be returned by reference

Filename: core/Common.php

Line Number: 257

A PHP Error was encountered

Severity: Warning

Message: Cannot modify header information - headers already sent by (output started at /home/speipl/public_html/system/core/Exceptions.php:185)

Filename: libraries/Session.php

Line Number: 688

System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Morley-IAS
Horizon Panels
  • General
  • Feature
  • Specification
The Horizon series of conventional control panels has been developed to provide a simple and reliable solution to the demands of today's fire detection solutions. The Horizon range has been designed with both installer and end users requirements in mind. For installers, Horizon offers an out of the box and on the wall solution. A combination of quick installation, an enhanced feature set and advanced programming allows installers to quickly and simply meet the demands of end user. Equipped with configurable class change inputs coincidence detection, programmable delays to allow alarm verification and the facility to interface to larger house alarm systems.
Simple, user friendly design Simple to install Intuitive to use 2. 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2
mechanical Dimensions: 318 x 356 x 96 mm (h x w x d) Weight: 2 Kg (approx, no batteries fitted) Construction: Fire retardant, ABS plastic moulded enclosure, sealed to IP30. Cable entry: 18 x 20mm knockouts in top of enclosure. 25 x 50 mm knockout in rear of enclosure. Operating Temperature : +5ºC to +35ºC Relative Humidity : 5% to 95% non condensing. electrical Operating voltage: 230 Vac 50/60 Hz (±15%) Internal Power supply: Output voltage +18.5 to +28.5 Vdc Output Current 1.8 Amps maximum Maximum Alarm load: 1 Amp Standby Batteries: Minimum capacity 2 x 12 V 2.8Ah Maximum capacity 2 x 12 V 7 Ah Standby Battery type: Sealed lead acid. Detection circuits : 2, 4 or 8 detection circuits. 2 mA per circuit (typically >20 detectors). Approved detectors: Apollo Series 60 wide voltage, Series 65 & Orbis. Morley-IAS Horizon HR2 Series System Sensor ECO1000, Series 300 & Vision. Digital Inputs: 2 configurable inputs (Class Change, Alert, Evacuate, Reset). Digital Input trigger: Extended Closing contact. External outputs: Sounder outputs: 2 monitored outputs. 0.5 Amps per circuit. Auxiliary output : +18.5 to +28.5 Vdc, 0.5 Amp. Optional Relay card : 1 x Fire relay (changeover contacts rating 30Vdc, 1 Amp). 1 x Fault relay (changeover contacts rating 30Vdc, 1 Amp).
//