A PHP Error was encountered

Severity: Notice

Message: Only variable references should be returned by reference

Filename: core/Common.php

Line Number: 257

A PHP Error was encountered

Severity: Warning

Message: Cannot modify header information - headers already sent by (output started at /home/speipl/public_html/system/core/Exceptions.php:185)

Filename: libraries/Session.php

Line Number: 688

System Product Enterprises (India) Pvt. Ltd.
Call us at: +91 22 43488488
Products Category

    A PHP Error was encountered

    Severity: Warning

    Message: mysql_fetch_array() expects parameter 1 to be resource, boolean given

    Filename: views/left.php

    Line Number: 36

Request Catalog
Fillup short form for request catalog


Home --> Fire Alarm Systems
DH 500 AC DC
  • General
  • Feature
  • Specification
The DH500 AC/DC series duct housing is designed to sample air currents passing through a duct and allows the early detection of developing fire. The DH500 AC/ DC duct housing will accommodate either the intelligent ionisation sensor or the intelligent optical sensor, either of which provides continuous analogue monitoring of the unit’s sensitivity and alarm verification from the panel. When sufficient smoke is sensed, an alarm signal is initiated at the control panel, monitoring the detector, and appropriate action can be taken to shut off fans, and blowers, change over air handling systems, etc. This can prevent the rapid distribution or isolation of toxic smoke and fire gases throughout the areas served by the duct system. The DH500 AC/DC duct detector system features the superior capabilities of an intelligent sensor in a unit that is easy to install and maintain, making this duct detector the new industry standard.
• Accommodates intelligent ionisation or optical detectors • Continuous sensitivity monitoring and alarm verification from the panel • Simple change of detector heads: twist-in, twist-out • Easy and quick mounting to round or rectangular ducts • Outputs for remote test station (separate 24 Vdc is required) • Air velocity rating from 150 to 1200 metres per minute (500 to 4,000 feet per minute) • Clear polycarbonate cover for convenient visual inspection of sampling tube filters • Rugged Noryl® housing (mounting portion) • Two Form-C auxiliary contacts • Powered outputs for remote LED and sounder/strobe (seperate 24 Vac/dc power required) • Three year limited warranty
mechanical Dimensions (HxWxD): 127 x 367 x 89 mm Weight: 1.8 Kg. (4 lbs) Operating temperature: - 10°C to 60°C Humidity: 10% to 93% non-condensing Air velocity: 150 to 1200 metres (500 to 4,000 feet) per minute electrical Operating voltage: 15 to 32 Vdc Current consumption: 200 μA at 24 Vdc 7 mA at 24 Vdc LED current nominal Terminals: SEMS screws with clamping plates for up to 2.5 mm2 (13 AWG) wire Auxiliary relay contacts: 100mA (minimum) 4 amps max at 28 Vdc. 7.5 amps max at 28 Vac.
//