MI-PSE & MI-ISE
  • General
  • Feature
  • Specification
The Morley-IAS MI-PSE (optical) and MI-ISE (ionisation) are analogue, addressable, low-profile smoke detectors designed for the ZX series intelligent multi protocol fire alarm control panels. Because the MI-PSE and MI-ISE are analogue addressable, the control panel can provide the operator with a pinpoint description of where the fire is located. The control panel is capable of not only knowing the detector’s location but exactly how much smoke is in the chamber of the detector. The detector may be set for different sensitivity settings appropriate to the environment of its location. The MI-ISE intelligent ionisation sensor incorporates a unique single-source chamber designed to respond quickly and dependably to a broad range of fires. The MI-PSE intelligent optical sensor’s unique sensing chamber is designed with superior signal to noise ratio. The optical chamber is engineered to sense the presence of smoke produced by a wide range of combustion sources. The MI-ISE and MI-PSE plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder.
• Low-profile design • Common base for optical, ionisation and thermal sensors • Addressable-analogue communication • Stable communication technique with noise immunity • Low stand-by current • Rotary decade 01 to 99 address switches • Remote LED output as standard • Dual LED design provides 360° viewing angle • Visible LED’s blink every time the detector is addressed (optional), and illuminate steady on alarm • Built-in functional test switch activated by external magnet • Optional relay, isolator, or sounder bases • LPCB approved
mechanical Dimensions (Height): 43 mm (installed in B501) 102 mm diameter Weight: 104 gr. (4 oz) Operating temperature: - 10°C to 60°C Relative humidity: 10% to 93% non-condensing electrical Operating voltage: 15 to 32 Vdc peak Current consumption: Stand by current: 200 μA @ 24 Vdc LED current: 7 mA @ 24 Vdc (“ON”) Terminals: SEMS screws with clamping plates for up to 2.5 mm2 (13 AWG) wire
//