DNRE
  • General
  • Feature
  • Specification
The InnovairFlex™ Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. The InnovairFlex DNRE intelligent non-relay photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. These units sense smoke in the most challenging conditions, operating in airflow speeds of 1.5m/s to 20.3m/sec, temperatures of −20°C to 70°C, and a humidity range of 0 to 95 percent (non-condensing). An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. A cover tamper feature was added to indicate a trouble signal for a removed or improperly installed sensor cover. The InnovairFlex housing provides a 20mm conduit knockout and ample space to facilitate easy wiring and mounting of relay module. The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories.
• Photoelectric, integrated low-flow technology • Air velocity rating from1.5m/s to 20.3m/sec • Versatile mounting options: square or rectangular configuration • Broad ranges for operating temperature −20°C to 70°C and humidity (0% to 95% non-condensing) • Patented sampling tube installs from front or back of the detector with no tools required • New Cover tamper signal • Increased wiring space with a newly added 20mm conduit knockout • Available space within housing to accommodate mounting of relay module • Easily accessible code wheels on sensor head (sold separately) • Clear cover for convenient visual inspection
Please see detector head installation manual for electrical specifications Accessory Current Loads at 24 VDC Device Standby Alarm RA100Z 0 mA 12 mA Max. RTS151/RTS151KEY 0 mA 12 mA Max. Physical Specifications Size: (Rectangular) 37 cm Length; 12.7 cm Width; 6.36 cm Depth (Square) 19.7 cm Length; 22.9 cm Width; 6.35 cm Depth Weight: 0.82 kg Operating Temperature Range: -20°C to 70°C Storage Temperature Range: -30° to 70°C Operating Humidity Range: 0% to 95% relative humidity non-condensing Air Duct Velocity: 1.5 to 20.3 m/sec
//